1/9/2024 0 Comments Rv temp monitorThey are typically robust and inexpensive and can be used over a wide range of temperatures.PT100 sensors measure the resistance deviation of the medium to determine its temperature and are sometimes called resistance temperature detectors, or RTDs. These sensors are known for their high accuracy and reliability.Infrared temperature sensors and thermographic cameras convert thermal radiation to an electrical signal to monitor temperature levels. These are ideal for circumstances where contact sensors cannot be used.Types of Humidity SensorCapacitive humidity sensors use humidity-dependent condensers to determine moisture output. These sensors are often used to measure the relative humidity in air conditioning units and HVAC systems.Resistive humidity sensors measure the electrical variation in conductive polymers and treated substrates. Even when your coach is in storage you may need to know.Low cost and small of size, these sensors are used in a variety of applications and appliances.Thermal conductor humidity sensors calibrate the deviation between the thermal conductivity of dry air versus moist air. I have also revised my alarm rules so I can get an earlier warning of when power is lost and not wait for a temp alarm to notify me. It worked, temps came back up to around 52F in the wet bay and AGS did its thing. I raised my lower SOC setpoint for GEN to come on from what I normally use and left. Granted, things aren't going to flash freeze, it takes time, but it wasn't what I wanted. No need for quiet hours in storage and that would have been 10 hours of no heat which surely would have reached below freezing temps. 2) Quiet hours still set from 10 PM to 8 AM. Bad idea, it could have helped me here, so it's enabled. I reviewed my AGS settings and had two mistakes: 1) I didn't have EXT INPUT enabled as I only use that in the summer to trigger GEN when air conditioning is needed and shore power is lost. I arrived and yeah, no power, and turned on the diesel burner. So yeah, I couldn't get the GEN to come on so off I go heading to the storage lot. My concern though was the outside air temp was now 15F and the dometic logic is to auto switch to furnace below a set temp, on mine that was tested to be around 32F. I figured I can trigger the GEN to come on my using my Wi-Fi thermostat from Micro-air to turn the heat pump on for zone 2 and that should trigger the GEN if AGS is setup correctly. I have OASIS AC I/II on but not diesel burner so I need a 120V source (shore or gen power). The storage lot is about 20-30 minutes from me and I really didn't want to have to drive up. SOC was down to 94% and it appeared the power had been out for several hours already. I logged in to VRM and sure enough power was out but is now back on and then it went out again. We had high winds and expected power outages. Last night around 8:30 PM I get an email that the wet bay has gone below my threshold of 37F. I have alarm rules setup in the web portal for Victron, a free service, to alarm me on various rules but one is wet bay temperature. I used two temperature monitoring systems, a Tempstick both in house and wet bay but also my solar setup by Victron has a temp sensor in the battery compartment and also the wet bay.
0 Comments
Leave a Reply. |
AuthorWrite something about yourself. No need to be fancy, just an overview. ArchivesCategories |